Control how long Notetaker keeps your meeting data
Last updated: November 11, 2026
Available on: Mac and Windows
Delete a past meeting to remove its Notetaker data outright, discard a short or failed recording, or check how long meeting audio is kept before it goes away on its own.
Keep a copy before deleting
Open the meeting from your meetings list or in its own notepad.
Choose Copy as Markdown from the header’s More actions (…) menu.
Paste the clipboard contents into another app, then save the copy.
Check the copy contains what you need before deleting. Success shows All meeting contents copied to clipboard or an invitation to connect AI tools; failure shows Failed to copy meeting.
The copy includes the title, participants, notes, Brief, summary, and transcript, including in-progress text and speaker labels.
Note: Where shown, Copy as Markdown is greyed out while copying or if Flow cannot identify the meeting. In the notepad, it appears only for an identified meeting with sharing available, and stays disabled during Preparing meeting….
How long meeting audio is kept
Audio retention is separate from transcript retention, and uploaded audio has a separate deadline from audio on your device.
Audio | Default retention | What it means |
Uploaded to Wispr | Scheduled for deletion 7 days from upload. | Refreshing a link or replacing the same upload does not extend the deadline. |
Local, fully processed | 7 days after the audio was last written. | Finishing processing does not remove it early. |
Local, unfinished processing | 30 days after the audio was last written. | This recovery window is never shorter than the processed-audio window. |
If uploaded-audio retention is disabled for your account, audio is deleted when processing ends. Failed deletion can delay removal beyond seven days; remaining uploaded audio expires after 35 days, and recovery copies keep the original deadline.
Any remaining local audio for deleted meetings or retention-deleted transcripts uses the shorter window. Automatic audio cleanup skips recording, paused, and still-finishing meetings. If retention deletes a transcript, the note remains.
Resume requires available local audio within the shorter window and an undeleted transcript; the longer window does not extend resume time. Once local audio is removed, resume and re-processing stop, but the meeting, transcript and summary remain.
Delete a meeting
Warning: Deleting a meeting is permanent and cannot be undone. It removes notes, summary, transcript, chats, audio and speaker-identification data across your devices, including local audio awaiting saving or processing, and starts without waiting for the audio-retention deadline. To remove less, delete only the Flow Summary: that permanently removes the summary and leaves your notes intact.
Find the meeting on the Flow homepage or in your meetings list.
Open More options (…) by hovering over its row, or use the notepad’s More actions (…) menu.
Select Delete.
Choose Delete in Delete meeting? to confirm, or Cancel to keep it.
Check that the meeting disappears from the homepage, meetings list and search results.
Deletion completes after Wispr confirms deletion or that the meeting is already gone. If the request fails first, local data stays intact and the row reappears with Couldn't delete the meeting. Please try again. — retry deletion.
While recording, the row menu is hidden; use the notepad. Flow stops the recording before deleting, then closes the notepad and returns to Notetaker.
Upcoming meetings have no Delete option; their controls menu appears only if the meeting has not ended and at least one control is editable. Notes shared with you have neither Delete nor Report in the notepad menu.
Delete meeting data in bulk
Where available, bulk deletion of meeting data includes recordings, transcripts, summaries and chats with Wispr. Deletion can take up to 30 minutes. If your organization retains meetings, they cannot be deleted this way.
Warning: This permanently deletes the selected data from Wispr Flow and this device and cannot be undone. Your account and settings stay.
Discard a short or failed recording
Warning: Discard on the cards below permanently removes a new recording and its local audio, except when protected by typed notes. Typed notes are never deleted automatically.
Automatic discard applies only to new recordings without typed notes, never resumed or crash-recovered meetings. It removes empty recordings with no audio or transcript, and failed starts with less than 10 seconds captured on each audio source. Failed-start discard requires expected live transcription that never connected, no transcript, and no offline start; stops for system-audio setup also qualify.
Started by mistake? offers Keep and Discard after live transcription connected but captured fewer than 20 words in the current segment. It excludes tour demos, system-audio-setup stops, live-transcript-off sessions and already-discarded recordings. On resumed recordings, Discard only dismisses the card; earlier content and newly appended words remain.
Couldn't start recording: meaningful audio — at least 10 seconds on either audio source — is saved on your device without a transcript or summary. Closing or ignoring the card does not delete it. Try again records into the same saved meeting, or starts a new one if none survived. On resumed recordings, or when none survived, Discard only closes the notepad.
If Live transcript unavailable offers Record offline or Cancel, the failed-start card is suppressed; choosing Record offline keeps audio on your device for transcription when back online. Missing microphone permission or recording-policy restrictions also suppress that card. A mid-session drop instead shows Connection lost: We lost the connection. Your audio was saved.
If a required consent notice cannot be posted
When your organization requires a consent notice and Flow cannot post it, discarding the meeting has the consequence below.
Warning: This removes the recording, notes and transcript. Nothing will be saved to Wispr, and this cannot be undone.
Still stuck?
If a meeting keeps reappearing after deletion, contact support with your platform, device, meeting date, error message and what you tried.