Microphone not working during Flow setup

Last updated: November 19, 2026

Available on: Windows

If the microphone test doesn't hear you, an error blocks setup, or your selected microphone is unavailable, check the input, microphone access, and other apps to get past the test.


Quick checks

  • Input: Select Change microphone and choose a built-in or wired/USB mic instead of Stereo Mix, a virtual/software mic or Bluetooth. Auto-detect (From computer settings) follows the Windows input; choosing a specific device overrides it for Flow.

  • Other apps: Close Zoom, Microsoft Teams, Google Meet, Discord, and recording or streaming software.

  • Verification: After each change, speak during the test. If the purple bars move, select Yes to continue setup; otherwise, try the next action below.

The test starts automatically. Flow selects a built-in microphone if one exists and you haven't chosen another input.

For a headset, connect it, optionally set it as your Windows input, then select it in Flow.

Microphone picker details

Inputs marked (Virtual) appear under Show other devices (N), which expands when a virtual input is selected. Collapsing it while a virtual device is selected switches the selection to Auto-detect.

Flow remembers a chosen physical microphone and prioritizes it; virtual inputs aren't added to device priorities.

Selecting AirPods during the test triggers a recommendation to change microphones; other Bluetooth headsets don't trigger that warning.


Match the error screen to the fix

Note: You can't dismiss an error screen with Escape or by clicking outside it. Flow checks your microphone every 2 seconds and closes the screen automatically when it works.

Open Sound Settings opens the classic Windows Sound control panel's Recording tab. After using Open Settings or Open Sound Settings, return to Flow to recheck permissions and retry microphone access automatically.

Connecting or disconnecting a microphone during the test refreshes the input list and restarts microphone testing.

Microphone access required

Both device-level microphone access and desktop-app access must be on.

  1. Click Open Settings to open Windows microphone privacy settings at Privacy & security → Microphone.

  2. Turn on Microphone access (or Microphone access for this device).

  3. Turn on Let desktop apps access your microphone (or Allow desktop apps to access your microphone).

No microphone detected

Refresh devices is unavailable for about 1.5 seconds while Checking… appears.

  1. Connect a microphone.

  2. Click Refresh devices.

  3. Click Open Sound Settings if detection still fails, and check that an input is enabled.

Microphone is in use

Another app can take the microphone even during the test.

  1. Close the microphone-using apps listed in Quick checks.

  2. Click Open Sound Settings if the error remains.

  3. Select a different input device.

  4. Click Restart Flow if the microphone is still unavailable.

Selected microphone unavailable

Your chosen microphone isn't connected; Flow won't silently switch to another input.

  1. Reconnect the microphone you picked earlier.

  2. Click Choose a different microphone if it remains unavailable.

  3. Select a connected input in the picker.

Microphone error

Flow couldn't start the microphone, including after an interrupted attempt.

  1. Click Restart Flow.

After a restart, return to the microphone test and repeat the purple-bar check.

After 60 seconds of continued failure during setup, Flow can't detect your microphone. appears for 15 seconds with a Restart Flow action. It clears if the microphone starts working.


If the error screen keeps coming back

  1. Open your microphone's Properties → Advanced from the Sound control panel's Recording tab.

  2. Turn off Allow applications to take exclusive control of this device in your microphone's sound properties in Windows.

  3. Restart your computer, then open Flow again.

  4. Reinstall Flow using the latest installer from the official Wispr Flow download page.

On a work computer, security software may block Flow from using your microphone. If these steps don't help, ask your IT team to allow microphone access for Flow.

Flow can't find your microphone after setup

After setup, Settings → General → Microphone → Change opens the same microphone picker.

  1. Reconnect the headset or microphone you were using.

  2. Click Choose Microphone if you see the Selected microphone is unavailable notification.

  3. Select a connected input.

Important: Disconnecting the microphone during dictation stops recording. Select Insert in the Microphone disconnected notification to insert the text recorded so far.

A newly connected higher-priority microphone is used from the next recording.


Still stuck?

Contact support if the microphone test remains blocked after these steps or the error returns after restarting Flow.

Note: Setup's Help button opens the feedback form Send a message to the Flow team. Use Talk to support to report an issue.

  • During setup: Right-click the Wispr Flow icon in your Windows system tray and select Talk to support, or write in from the Wispr Flow support page.

  • After setup: In Flow's sidebar, open Help → Get in touch → Talk to support. Messages sent through Talk to support include system details and app preferences when the preferences file is 3 MB or smaller.

  • Include: Your platform, selected microphone name, an error screenshot, and the steps you tried. On a work computer, include whether your IT team has confirmed nothing is blocking Flow.

In Report an issue, choose Issue as the Request type. You can attach one image up to 10 MB.

If sending fails, Flow shows Couldn't send and copies your message to the clipboard. Paste it to retry.